VOLTAGEDROPCALCULATOR
Zastosuvannia 11 khv

Padiinnia Napruhy v Systemakh Zberihannia Enerhii: DC Kably Batarei, Fider Invertora ta Rezervnyi Shchyt

Systemy zberihannia enerhii shvydko pokazuiut, koly providnyk vybrano za zvychkoiu. Fider mozhe vyhliadaty normalno za navantazhuvalnoiu zdatnistiu, ale vse odno z iisty zapas napruhy rezervnoho invertora. Navit korotkyi na vyhliad DC-kabel mozhe vtrachaty vidchutnu enerhiiu, koly strum rozriadu zrostaie do soten amper.

Na praktytsi potribno pereviriaty ves shliakh: DC mizh batareieiu ta invertorom, AC mizh invertorom i shchyton krytychnykh navantazhen, a takozh bud-yakyi fider mizh servisnym obladnanniam i rezervnym shchyton. Dlia NEC korysni Article 706, za nayavnosti lokalnoi heneratsii takozh Article 705, a takozh informational notes u 210.19(A)(1) ta 215.2(A)(1). Dlia proiektiv IEC praktychnymy oriientyramy ye IEC 60364-5-52 ta IEC 60364-8-2. NEC IEC

Chomu Batareini Systemy Potrebuiut Okremoi Perevirky Padiinnia Napruhy

Batareini kola chasto pratsiuiut na nyzhchii DC-napruzi ta vyshchomu strumi, tomu navit mala opirnist daie pomitnyi vidsotkovyi spad.

Systema mozhe vyhliadaty normalno pid chas zaryadu i slabko pid chas rozriadu na rezervni navantazhennia.

Hibrydni invertory, krytychni shchyty, peremykalne obladnannia ta zovnishni batarei stvoriuiut kilka dilianok, yaki potribno rozghliadaty razom.

DIY-proiekty chasto zupyniaiutsia na avtomati ta iemnosti batarei, todi yak elektryky ta inzhenery povynni zakhyshchaty takozh produktyvnist invertora i maybutnie rozshyrennia.

Punkty Kodu ta Standartiv, Yaki Varto Poznachyty na Plani

  • NEC Article 706: ESS potrebuie pravylnykh zasobiv vidkliuchennia, doboru providnykiv, zakhystu vid nadstrumu ta vidpovidnoho montazhu.
  • NEC Article 705: yakshcho batareina systema vzaiemodiie z mistsevoiu heneratsiieiu abo interconnect-obladnanniam, rishennia shchodo fidera ta pidkliuchennia potribno koordynuvaty.
  • NEC 210.19(A)(1) ta 215.2(A)(1): bahato proiektuvalnykiv vse shche orientuiutsia pryblyzno na 3% na dilianu ta 5% zahalom.
  • IEC 60364-5-52 ta IEC 60364-8-2: pidtverdte sposob prokladannia, hrupuvannia, umovy dovkillia ta ochikuvannia vid roboty prosumer-systemy do zatverdzhennia kintsevoho rozmiru.

Typovi Planovi Vypadky dlia Akumuliatornoho Zberihannia

Tse planovi znachennia, a ne zaminnyk instruktsii vyrobnyka chy ostatochnykh tablyts. Vony dobre pokazuiut, yak shvydko padiinnia napruhy staie vyznachalnym u batareinykh proiektakh.

ScenariiVidstan i navantazhenniaProvidnykPrybl. padinnia
48V batareia do invertora2 m v odyn bik, 200A DC50 mm2 Cublyzko 0.31V / 0.65%
48V batareia do invertora5 m v odyn bik, 150A DC35 mm2 Cublyzko 0.79V / 1.64%
240V invertor do rezervnoho shchyta110 ft / 34 m v odyn bik, 40A AC6 AWG Cublyzko 4.3V / 1.8%
230V hibrydnyi invertor do navantazhen35 m v odyn bik, 32A AC10 mm2 Cublyzko 4.1V / 1.8%

Pryklady z Konkretnymy Chyslamy

48V blok baterii, 200A rozriad, 2 m DC-kabel

Dlia 50 mm2 midi z oporom blyzko 0.387 om/km dvorukhy padiinnia stanovyt blyzko 0.31V. Tse zdayetsia malym, ale na 48V systemi tse vzhe blyzko 0.65%. Menshyi kabel vidrazu zabere tsyi zapas u invertora.

240V batareinyi invertor do krytychnoho shchyta, 40A, 110 ft

Za 6 AWG midi z pryblyzno 0.491 om na 1000 ft padiinnia fidera stanovyt blyzko 4.3V, tobto 1.8% na 240V. Chasto tsoho dosyt, ale yakshcho verkhnii fider vzhe vykorystovuie chastynu 5%-ho byudzhetu, 4 AWG zazvychaino chystishe rishennia.

230V odnofaznyi hibrydnyi invertor, 32A, marshrut IEC 35 m

Za 10 mm2 midi z blyzko 1.83 om/km padiinnia bude blyzko 4.1V, tobto 1.8% na 230V. Variant 6 mm2 pidnimetsia maizhe do 6.9V abo 3.0% i zalyshyt znachno menshyi komfort dlia rezervnykh navantazhen.

Perevirnyy Spysok pered Zatverdzhennia Rozmiru Providnyka

  • Perevirte naihirshyi rezhym roboty: zaryad, rozriad, pidtrymka piku chy povnyi bezperervnyi vykhid invertora.
  • Vymiriai te spravzhniu dovzhynu v odyn bik dlia kozhnoho sehmenta, a ne pryipuskai te, shcho batareia ta invertor “dostatno blyzko”.
  • Trymaite obmezhennia vyrobnyka shchodo kabeliu, reitynhy nakonechnykiv, prostir dlia zhybu ta vymohy do DC-vidkliuchennia na tomu samomu arkushi, shcho i rozrakhunok padiinnia.
  • Perehliadaite yak DC-shliakh, tak i AC-shliakh, bo sylnyi batareinyi kabel ne vriatuie slabkyi rezervnyi fider.
  • Yakshcho piznishe mozhlyve dodannia moduliv, bilshoi vykhidnoi potuzhnosti abo bilshoho krytychnoho shchyta, zalyshte zapas vzhe zaraz.

Rozrakhuite Bataieryinyi Marshrut pered Prokladan niam Kabeliu