240V Voltage Drop Calculator

Professional calculator for 240 volt circuits. Essential for EV chargers, dryers, ranges, HVAC, and pool equipment.

240V AC Calculator

Need Three-Phase or Advanced Features?

Open Full Calculator

240V Circuit Applications

EV Charger Installation

Level 2 EV chargers typically require 40A-50A circuits. Wire sizing is critical for long garage runs.

  • • 40A charger: 8 AWG minimum
  • • 50A charger: 6 AWG minimum
  • • Consider 80% continuous load rule

HVAC Systems

Central air conditioners and heat pumps use 240V for efficiency. Outdoor unit wire runs can be long.

  • • Check nameplate amperage
  • • MCA (Min Circuit Ampacity)
  • • MOCP (Max Overcurrent Protection)

Electric Dryers

Standard dryers require 30A 240V circuits with 10 AWG wire.

Electric Ranges

Ranges typically need 50A circuits with 6 AWG wire for full cooking capacity.

240V Wire Size Chart

Breaker Wire Size Common Application
20 Amp 12 AWG Window AC, small equipment
30 Amp 10 AWG Dryer, water heater
40 Amp 8 AWG EV charger, cooktop
50 Amp 6 AWG Range, large EV charger
60 Amp 4 AWG Sub-panel, large HVAC